Brandschutz Baukastensystem 42 mm

PRIORIT Modular fire protection system "System 42"

System for the decorative structural fire protection

Wall solutions

Room in room solutions

 

Goals of the modular fire-protection system

Structural fire protection is a permanent component of buildings for protecting persons residing inside of them and who should leave the building safe and unharmed when a fire occurs. It includes a large number of regulations, above all, the specific national building codes which describe the basic requirements. Architects and professional planners must put these basic requirements into practice as practically and effectively as possible, generally by fire-protection planning or a fire-protection concept and the further performance levels for the planning and construction of the specific building.

The "jumble" of regulations paired with the building products and the verification required by the building authorities do not exactly make the entire topic of fire protection easy for architects, professional planners, building owners, operators and trades performing the work. The fact that we are currently in a prolonged transition phase between national and European verification for building products, which requires continuous updating, makes the task even more difficult. This means that the topic of fire protection must be dealt with more intensively, both now and in the future. Along with these challenges, the topic of architecture, optics, functionality, sustainability and cost optimisation should be consolidated for structural fire protection.

A possible solution for meeting these requirements on structural fire protection is the "System 42" modular fire-production system from PRIORIT AG, which is specially designed for technical building equipment (TGA) and the expansion of rescue routes within buildings.

Brandschutz-Baukastensystem Anwendungsbild

Application example

  • Reference picture modular fire protection system
  • Reference picture modular fire protection system
  • Reference picture modular fire protection system
  • Reference picture modular fire protection system
  • Reference picture modular fire protection system
  • Reference picture modular fire protection system

System modules and evidence

The "System 42" modular fire-protection system consists of several independent fire-resistant non-flammable construction products with a system thickness of just 42 mm, which have been tested in combination with each other and have a general usability certificate from the building authorities.

  • Plate material 42 mm with decorative surface (decoration, veneer, paint, metal)
    Non-flammable, evidence: CE declaration of performance, designation: PRIODEK H
    Basis for the following building products
  • Wall system 42 mm
    Fire retardant / fire resistant, non-flammable, smoke protection evidence: General test certificate from the building authorities (AbP), designation: PRIOWALL
  • Ceiling system 42 mm
    Fire retardant / fire resistant, non-flammable, smoke protection evidence: General test certificate from the building authorities (AbP), designation: PRIOCEIL
    Tested in combination with wall system 42 mm
  • Doors 42 mm
    Fire retardant / fire resistant, non-flammable, smoke protection
    Evidence: General approval by the building authorities (AbZ), designation: PRIODOOR FSA
    Tested in combination with wall system 42 mm
  • Inspecition opening closures 42 mm
    Fire retardant / fire resistant, non-flammable, smoke protection
    Evidence: General approval by the building authorities (AbZ), designation: PRIODOOR ETX
    Tested in combination with wall system 42 mm
  • Smoke removal dampers 42 mm
    Fire resistant, non-flammable, smoke protection
    Evidence: Declaration of performance (CE), designation: PRIODOOR ETX-RDA
    Tested in combination with wall system 42 mm
  • Fire protection damper
    Fire resistant, non-flammable, smoke protection
    Evidence: Declaration of performance (CE), designation: PRIODOOR BSK
    Tested in combination with wall system 42 mm
  • Bulkhead accessories
    Fire retardant / fire resistant, smoke protection
    Evidence: General approval by the building authorities (AbZ), external manufacturer:
    Tested in combination with wall system and ceiling system 42 mm
  • Ventilation accessories
    Fire retardant / fire resistant, smoke protection
    Evidence: General approval by the building authorities (AbZ), external manufacturer:
    Tested in combination with wall system and ceiling system 42 mm

Design and typical application "System 42"

Designs System 42 - I-Shaped
I-shaped
Designs System 42 - L-shaped
L-shaped
Designs System 42 - U-shaped
U-shaped
Designs System 42 - Freestanding
Freestanding

The "System 42" modular fire protection system can be used to implement  various designs either independently or in combination with fire-resistant components already existing in the building such as systems in the I, L, U shape or as a room in the room system.  Everything in combination with doors, inspection-opening closures, smoke-removal dampers, fire-protection dampers, bulkheads or ventilation. The decorative surfaces (decor, veneer, paint or metal) also make it possible to ideally combine the systems with architecture and historical monuments.
The "System 42" modular fire-protection system is particularly suited for the partitioning of the technical building equipment or materials stored in rescue routes, for installation shafts and their large-scale inspections, for outflow shafts for the RDA, and for special door elements, escape tunnels, storage rooms or electrical service rooms.  Individual components of the "System 42" modular fire-protection system such as doors, inspection-opening closures, and smoke-removal dampers can be combined with other wall types.

  • The following designs are possible: I, L, or U-shaped
  • Design with/without ceiling or as complete room (for example: room-in-room solution)
  • Connection of the wall elements to unfinished floor or ceiling
  • Connection of the ceiling elements to solid walls
  • Connection of the solid side walls or paneled steel girders 

Typical "System 42" application 

  • Electrical equipment partitions (electrical distributors, gas meters, etc.) and/or stored materials (documents) in escape and rescue routes
  • Installation ducts for the technical building equipment in rescue routes
  • Exhaust ducts for smoke-pressure systems (RDA) in escape routes
  • Door elements in special sizes
  • Construction of complete escape tunnel
  • Planning and production of storage rooms
  • Electrical service rooms in accordance with MEltBauVO (standard electrical building ordinance)
  • Fire-resistant rooms (e.g. in accordance with MLAR standard cable system directive)

    Everything important at a glance

    Short summary of system42:

    • Modular system for fire protection in new and existing buildings
    • Creative freedom for architects and planner
    • Flexible combination of ceilings, walls, doors and inspection doors
    • All building components non-combustible material (A2, 42mm) and 90 minutes fire resistant

      Basic components in system 42

      PRIODEK H – Fireproof building material
      (A2-s1, d0)
      Building material PRIODEK H

      The foundation of System 42 is the fireproof building material PRIODEK H used in it – a joining material with a decorative surface. PRIODEK H is extremely hard and resistant and can be coated with many different low maintenance and chemical resistant surfaces.

       

       

      Product details PRIODEK H
      The following surfaces are available on request:
      • Decors (Uni-,Wood-, Stone-, Metal decors)
      • Varnish
      • Thin-gage sheet metal
      • Wood veneer
      Overview PRIORIT surfaces
      PRIOWALL – Wall
      (F30/EI30, F90/EI90, A2-s1, d0, smokeproof)
      Basic components wall - PRIOWALL

      PRIODEK H wall system 42 mm thick and without under-construction, max. height of 4000 mm, many different width available, with/without ceiling up to 800 mm

       

       

      Product details Wall system PRIOWALL
      Tender specifications PRIOWALL 90 minutes
      Tender specifications PRIOWALL 30 minutes
      PRIODOOR FSA – Doors
      (T30-RS/T90-RS, F30/EI30, F90/EI90)
      Basic components - doors PRIODOOR FSA

      Passageway door made of PRIODEK H 42 mm thick with bloc architrave, single and double door, with/without fire protection glass

       

       

      Product details Feuerschutzabschluss PRIODOOR FSA
      Tender specifications PRIODOOR FSA 30 minutes
      Tender specifications PRIODOOR FSA 90 minutes
      PRIODOOR ETX – Inspection Door
      (F30/EI30, F90/EI90, A2-s1, d0, smokeproof)
      Basic components - inspection doors PRIODOOR ETX

      Inspection doors made of PRIODEK H 42 mm thick with bloc architrave, single and double door, with/without glass glazed (same construction as PRIODOOR FSA), options with ventilation systems

       

       

      Product details Inspection door PRIODOOR ETX
      Tender specifications PRIODOOR ETX 30 minutes
      Tender specifications PRIODOOR ETX 90 minutes
      PRIODOOR ETX RDA – Smoke damper
      (F 90/EI 90; A2-s1, d0; smokeproof)
      Basic components - smoke damper PRIODOOR ETX RDA

      Smoke damper made of PRIODEK H in Systemstärke 42 mm thick with bloc architrave, for horizontal as well as vertical applications in RDA outlet ducts

       

       

      Product details to PRIODOOR ETX RDA, horizontal
      Product details to PRIODOOR ETX RDA, vertical
      PRIOCEIL – Ceiling
      (F 30/EI 30; F 90/EI 90; A2-s1, d0; smokeproof)
      Basic components - ceiling PRIOCEIL

      Ceiling system made of PRIODEK H 42 mm thick, which can be easily and neatly constructed, converted and expanding using connectors.

       

       

      Product details Ceiling system PRIOCEIL
      Tender specifications PRIOCEIL 30 minutes
      Tender specifications PRIOCEIL 90 minutes
      PRIODOOR VENT – Ventilation elements
      (F 30/EI 30; F 90/EI 90; A2-s1, d0; smokeproof)
      Basic components - ceiling PRIOCEIL

      Universally applicable, self closing ventilation elements of PRIODEK H in 42 mm with block frame for mounting on the wall

       

       

      Product details ventilation element PRIODOOR VENT
      Tender specifications PRIODOOR VENT 30 minutes
      Tender specifications PRIODOOR VENT 90 minutes

      Accessory components in system 42

      Partitioning
      Accessory components - Partitioning

      Partitioning in wall system PRIOWALL or ceiling system PRIOCEIL for cables and tubes

      Fire protection glasses
      Accessory components - Fire protection glasses

      Fire protection glasses for fire resisting closure PRIODOOR ETX or inspection doors PRIODOOR ETX

      Ventilation systems
      Zubehörkomponenten - Schottungen

      Ventilation systems for wall system PRIOWALL or inspection doors PRIODOOR ETX

      Ventilation bulkhead
      Zubehörkomponenten - Lüftungsschotts

      Ventilation bulkhead for wall system PRIOWALL or ceiling system PRIOCEIL

      Green Building mit PRIORIT DGNB LEED