Maintenance of Performance

 
Interior and Design
 
Ventilation and Smoke Control System
 
Separation Fire Sections
 
Separation Building Services

PRIORACK FEK

Compact Electrical Operating Room
  • Fire resistance 90 minutes: fire-resistant
  • EI 90/F 90 classification wall/ceiling
  • T 90-RS classification of door
  • Door are smoke-tight, tested for continuous operation
  • Protection rating according to IP 54
System 42
fire-resistance-90
smoke-protection
material-and-decor
dust
safe
chem
h2o
din
en
u-components
Prospectus PRIORACK FEK
download PRIORACK FEK

PRIOROOM FEM

Electrical Operating Room, Individual
  • Fire resistance 90 minutes: fire-resistant
  • Wall: EI 90/F 90 classification
  • Ceiling: EI 90 a<->b/F 90
  • T 90-RS classification of door(s)
  • Door(s) are smoke-tight, tested for continuous operation
System 42
fire-resistance-90
smoke-protection
material-and-decor
safe
chem
din
en
u-components
Prospectus PRIOROOM FEM
download PRIOROOM FEM

PRIOELEC ES

Free-Standing Electrical Cabinets
  • Fire resistance of 90 min, fire resistant
  • Suitable for maintenance of performance for 90 minutes
  • Smoke protection
  • Empty case with high mechanical resistance
  • Integrated base accessible from all sides and with removable front panel

fire-resistance-90
smoke-protection
material-and-decor
chem
din
en
u-components
Prospectus PRIOELEC ES
download PRIOELEC ES
Operation Instructions
download PRIOELEC ES

PRIOELEC ESL

Free-Standing Electrical Cabinets „Light”
  • Fire resistance of 30 min, fire-retardant
  • Suitable for maintenance of performance for 30 minutes
  • Smoke protection, cold-smoke-proof
  • Integrated base, can be driven under
fire-resistance-30
smoke-protection
material-and-decor
chem
din
en
u-components
Prospectus PRIOELEC ESL
download PRIOELEC ESL
Operation Instructions
download PRIOELEC ESL

PRIOELEC EH

Electro Hanging Cabinet
  • Fire resistance of 90 min, fire resistant
  • Suitable for maintenance of performance for 90 minutes
  • Smoke protection
  • Empty case with high mechanical resistance
  • Ventilation system in the back of cabinet
fire-resistance-90
smoke-protection
material-and-decor
chem
din
en
u-components
Prospectus PRIOELEC EH
download PRIOELEC EH
Operation Instructions
download PRIOELEC EH

PRIOELEC EHL

Elektro-Hängegehäuse „Light“
  • Fire resistance of 30 min, fire-retardant
  • Classification: Suitable for maintenance of performance for 30 minutes
  • Smoke protection
  • Integrated ventilation system
fire-resistance-30
smoke-protection
material-and-decor
chem
din
en
u-components
Prospectus PRIOELEC EHL
download PRIOELEC EHL
Operation Instructions
download PRIOELEC EHL

PRIOELEC EW

Electro Wall Recessing Cabinet
  • Fire resistance of 30/90 min, fire-retardant, fire resistant
  • Suitable for maintenance of performance for 30/90 minutes
  • Smoke protection
  • Empty case for wall recessing

fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
chem
din
en
u-components
Prospectus PRIOELEC EW
download PRIOELEC EW

PRIOELEC EK90-M

Electro Terminal Box with Equipment
  • Fire resistance 90 minutes: fire-resistant terminal block
  • For maintenance of performance for 90 minutes
  • Fire chamber test, according to DIN 4102-2
  • Safety class I
  • Protection rating according to IP 54
fire-resistance-90
chem
din
en
Prospectus PRIOELEC EK90-M
download PRIOELEC EK90-M
Operation Instructions
download PRIOELEC EK90-M

PRIOELEC EK

Electro Terminal Box without Equipment
  • 30/90 minutes fire resistance, fire retardant, fire resistant
  • Classification: for maintenance of performance for 30/90 min.
  • Cabinet with high mechanical resistance for surface mounting
  • Demountable frame plate system for easy cable entry

fire-resistance-30
fire-resistance-90
material-and-decor
chem
din
en
u-components
Prospectus PRIOELEC EK
download PRIOELEC EK