Separation Building Services

 
Interior and Design
 
Ventilation and Smoke Control System
 
Separation Fire Sections
 
Maintenance of Performance

PRIOWALL

Installation Wall System
  • 30/90 minutes fire resistance, fire retardant, fire resistant
  • EI 30/F 30, EI 90/F 90 classification including inspection openings
  • Smoke protection
  • Protection rating according to IP 42
System 42
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOWALL
download PRIOWALL
Text for Tender 30 Min
download PRIOWALL download PRIOWALL
Text for Tender 90 Min
download PRIOWALL download PRIOWALL
Operation Instructions
download PRIOWALL

PRIOCEIL

Ceiling system
  • 30/90 minutes fire resistance, fire retardant, fire resistant
  • EI 30/F 30 (above and below), EI 90/F 90 (above) classification
  • Smoke protection
  • Protection rating according to IP 42
System 42
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOCEIL
download PRIOCEIL
Text for Tender 30 Min
download PRIOCEIL download PRIOCEIL
Text for Tender 90 Min
download PRIOCEIL download PRIOCEIL

PRIODOOR EVX

Fire protection barrier, Surface-Mounted
  • 30/90 minutes fire resistance, fire retardant, fire resistant
  • EI 30/F 30, EI 90/F 90 classification
  • Smoke protection
  • Protection rating according to IP 42
  • Safety class II
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIODOOR EVX
download PRIODOOR EVX
Operation Instructions
download PRIODOOR EVX

PRIODOOR FLEX

Inspection door, 3 to 5 leaf without center bar
  • 30/90 minutes fire resistance, fire retardant, fire resistant
  • EI 30/F 30, EI 90/F 90 classification
  • Smoke protection
  • Leak-proof closing
  • Protection rating according to IP 42
  • Safety class II
System 42
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components

PRIODOOR ETX

Inspection Closure universal
  • 30/90 minutes fire resistance, fire retardant, fire resistant
  • EI 30/F 30, EI 90/F 90 classification
  • Smoke protection
  • Leak-proof closing
  • Safety class II; Protection rating according to IP 42
  • International approvals: CH
System 42
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIODOOR ETX
download PRIODOOR ETX
Operation Instructions
download PRIODOOR ETX

PRIODOOR ETX A

Inspection door, flush with the adjacent areas
  • 30/90 minutes fire resistance, fire retardant, fire resistant
  • EI 30/F 30; EI 90/F 90 classification
  • Smoke protection
  • Leak-proof closing
  • Protection rating according to IP 42
  • Safety class II
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIODOOR ETX A
download PRIODOOR ETX A
Operation Instructions
download PRIODOOR ETX A

PRIODOOR ETX E

Inspection opening cover, with the adjacent areas
  • Fire resistance of 30/90 min, fire-retardant, fire resistant
  • EI 30/F 30, EI 90/F 90 classification
  • Smoke protection
  • Leak-proof closing
  • Protection rating according to IP 42
  • Safety class II
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIODOOR ETX E
download PRIODOOR ETX E
Operation Instructions
download PRIODOOR ETX E

PRIOHYD

Integral Shaft Enclosures
  • Fire resistance of 90 minutes, F 90 / EI 90
  • To be applied according to sample circuit system guidelines in shafts
  • For Extinguisher hose installations and wall hydrants according to DIN 14461
  • Non combustible composite material, classified A2 – s1, d0
  • Protection against drafts, cold smoke and hot combustion gases
fire-resistance-90
smoke-protection
material-and-decor
chem
h2o
din
en
u-components
Product Flyer
download PRIOHYD
Text for Tender 90 Min
download PRIOHYD download PRIOHYD
Operation Instructions
download PRIOHYD

PRIOELEC ES

Free-Standing Electrical Cabinets
  • Fire resistance of 30/90 min, fire-retardant, fire resistant
  • Classification: suitable for fire load insulation of 30/90 minutes
  • Smoke protection
  • Protection rating according to IP 42
  • Safety class II
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOELEC ES
download PRIOELEC ES
Operation Instructions
download PRIOELEC ES

PRIOELEC ESL

Free-Standing Electrical Cabinets „Light”
  • Suitable for a smoke-tight and fireresistant separation of electrical distributors in rescue routes
  • Fire resistance of 30 min, fire-retardant
  • Classification: suitable for fire load insulation of 30 minutes
  • Smoke protection
  • Protection rating according to IP 42
  • Safety class II
fire-resistance-30
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOELEC ESL
download PRIOELEC ESL
Operation Instructions
download PRIOELEC ESL

PRIOELEC EH

Electro Hanging Cabinet
  • Fire resistance of 30/90 min, fire-retardant, fire resistant
  • Classification: suitable for fire load insulation of 30/90 minutes
  • Smoke protection
  • Protection rating according to IP 42
  • Safety class II
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOELEC EH
download PRIOELEC EH
Operation Instructions
download PRIOELEC EH

PRIOELEC EHL

Elektro-Hängegehäuse „Light“
  • Suitable for a smoke-tight and fire-resistant separation of electrical distributors in rescue routes
  • Fire resistance of 30 min, fire-retardant
  • Classification: suitable for fire load insulation of 30 minutes
  • Smoke protection
  • Protection rating according to IP 42, Safety class II
fire-resistance-30
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOELEC EHL
download PRIOELEC EHL
Operation Instructions
download PRIOELEC EHL

PRIOELEC EW

Electro Wall Recessing Cabinet
  • Fire resistance of 30/90 min, fire-retardant, fire resistant
  • Classification: suitable for fire load insulation of 30/90 minutes
  • Smoke protection
  • Protection rating according to IP 42
  • Safety class II
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOELEC EW
download PRIOELEC EW

PRIOELEC EU

Fireproof Distribution Cubicle
  • Fire resistance of 30/90 min, fire-retardant, fire resistant
  • Classification: suitable for fire load insulation of 30/90 minutes
  • Smoke protection
  • Protection rating according to IP 42
  • Safety class II
fire-resistance-30
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOELEC EU
download PRIOELEC EU
Operation Instructions
download PRIOELEC EU

PRIODIS Basic

Secure monitor housing
  • Smoke protection
  • Encapsulation of fire load
  • Protection rating according to IP 54
smoke-protection
material-and-decor
dust
h2o
Prospectus PRIODIS Basic
download PRIODIS Basic
Operation Instructions
download PRIODIS Basic

PRIODIS 30

Secure monitor housing
  • Tested and certified fire protection for monitors in rescue routes
  • Fire resistance of 30 min., fire-retardant
  • Smoke protection
  • Encapsulation of fire load
  • Protection rating according to IP 54
fire-resistance-30
smoke-protection
material-and-decor
dust
h2o
Prospectus PRIODIS 30
download PRIODIS 30
Text for Tender 30 Min
download PRIODIS 30 download PRIODIS 30
Operation Instructions
download PRIODIS 30

PRIODOC

Fire Resistant Document Cabinet
  • Fire resistance 90 minutes: fire-resistant
  • EI 90 classification
  • LSF60P classification
  • ECB*S certified double-leaf cabinet
  • Smoke protection
  • Suitable for fire-resistant storage of record
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
ecb-s
din
en
u-components
Prospectus PRIODOC
download PRIODOC
Text for Tender 90 Min
download PRIODOC download PRIODOC
Operation Instructions
download PRIODOC

PRIOCOPY

Fire-Resistant Copier Room
  • Fire resistance 90 minutes: fire-resistant
  • EI 90/F 90 classification walls, ceiling
  • T 90-RS classification of side doors
fire-resistance-90
smoke-protection
material-and-decor
dust
chem
h2o
din
en
u-components
Prospectus PRIOCOPY
download PRIOCOPY
Text for Tender 90 Min
download PRIOCOPY download PRIOCOPY
Operation Instructions
download PRIOCOPY