Physical IT Protection

PRIORIT HSRZ

High-security Data Centre - Room Cell
  • 180 minutes fire resistance, fire-resistant
  • F 180 classification
  • Compliance with the limits specified in EN 1047 Part 2
  • ECB*S certification
  • System test by official material testing institute
  • Protection rating according to IP 56
smoke-protection
dust
safe
chem
h2o
ecb-s
din
en
fire-resistance-180
limit-90-min
magnetic
Prospectus PRIORIT HSRZ
download PRIORIT HSRZ

PRIORIT HSRZ CONT

Mobile high-security room cell in containers
  • Fire resistance 180 minutes (Element testing for wall, ceiling, floor)
  • Fire resistance 90 minutes (Element testing for doors, penetration seals)
  • Certified to EN 1047-2
  • ECB-S certified container
  • CES certificate for transport
  • Smoke control
smoke-protection
safe
chem
h2o
ecb-s
din
en
fire-resistance-180
limit-90-min
magnetic

PRIOROOM IT

Fire-Resistant Room
  • 90 minutes fire resistance, fire resistant
  • EI 90/F 90 classification walls/ceiling
  • Limits according to EN 1047-2
  • T 90 RS classification of door(s)
  • Smoke-tight doors, tested for continuous operation
  • Protection rating according to IP 54.
System 42
fire-resistance-90
smoke-protection
material-and-decor
dust
safe
chem
h2o
din
en
u-components
limit-90-min
Prospectus PRIOROOM IT
download PRIOROOM IT

PRIOWALL IT

Fire-Resistant Wall and Door System
  • 90 minutes fire resistance, fire resistant
  • EI 90/F 90 classification of wall
  • T 90 RS classification of door(s)
  • Limits according to EN 1047-2
  • Smoke-tight door(s), tested for continuous operation
System 42
fire-resistance-90
smoke-protection
material-and-decor
dust
safe
chem
h2o
din
en
u-components
limit-90-min
Prospectus PRIOWALL IT
download PRIOWALL IT
Operation Instructions
download PRIOWALL IT

PRIORACK IT

Fire-Resistant Safety Rack
  • 90 minutes fire resistance, fire resistant
  • EI 90/F 90 classification walls/ceiling
  • Limits according to EN 1047-2
  • T 90 RS classification of door(s)
  • Protection rating according to IP 54.
System 42
fire-resistance-90
smoke-protection
material-and-decor
dust
safe
chem
h2o
din
en
u-components
limit-90-min
Prospectus PRIORACK IT
download PRIORACK IT
Operation Instructions
download PRIORACK IT

PRIORACK IT F90 COMPACT

Fire-Resistant Safety Rack Compact
  • 90 minutes fire resistance, fire resistant
  • EI 90/F 90 classification
  • T 90 RS classification of door
  • Smoke-tight door, tested for continuous operation
  • Protection rating according to IP 54
fire-resistance-90
smoke-protection
material-and-decor
dust
safe
chem
h2o
din
en
u-components
Prospectus PRIORACK IT F90 COMPACT
download PRIORACK IT F90 COMPACT
Operation Instructions
download PRIORACK IT F90 COMPACT